Dichroic beamsplitters (45°)

These Interference Band pass Filters are used to isolate and transmit a narrow wavelength that is required and block all other wavelengths through reflection.

This range of Interference Band pass Filters consist of an all-dielectric coating along with other coatings for additional blocking and cemented together to form a stack. The individual filters are mounted in nested rings, providing a labyrinth epoxy edge seal for greatly extended life. Although these are mounted, unmounted type can be supplied at special request. These Interference Band pass Filters are all typically 3-7 cavity.

Uses include line selection, laser signal selection, colorimetry and fluorimetry. They can also be used for imaging. When using high powers the reflective side must be towards the incoming light.
 

Knight Optical > Filters > Dichroic beamsplitters (45°) > Short-wave reflecting

Only UK and EU customers are charged VAT at 17.5%, customers outside the EU and EU customers based outside the UK who have a valid EU VAT number will not be charged VAT

Bulk Discounts!
Where (B) appears next to a price below, bulk prices are available, click the (B) button to view!


PDFPart No.Size/dimensions (mm)Thickness (mm)TWL (T=50%) nmTransmission band (nm)Reflection band (nm)PriceQtyBuy
410FDB1625
25 x 16
1
410 } UV
440-700
340-390
£20.00

475FDB1625
25 x 16
1
475 } Blue
525-800
380-450
£20.00

490FDB1625
25 x 16
1
490 } Blue
520-760
400-450
£20.00

530FDB1625
25 x 16
3
530 } UV/blue
600-120
325-475
£16.75

700FCQ2515
25 x 15
3
700 } Visible !!< λ >!!
800-1200
425-650
£12.75

410FDB4025
40 x 25
1
410 } UV
440-700
340-390
£32.00

475FDB4025
40 x 25
1
475 } Blue
525-800
380-450
£28.00

490FDB4025
40 x 25
1
490 } Blue
520-760
400-450
£32.00

530FDB4025
40 x 25
3
530 } UV/blue
600-120
325-475
£28.00

700FCQ4025
40 x 25
3
700 } Visible !!< λ >!!
800-1200
425-650
£18.75

Knight Optical > Filters > Dichroic beamsplitters (45°) > Short-wave reflecting
Dimensions 
Diameter:+0 / -0.3mm
Thickness:5-6mm
Clear aperture: 
   12.5mm dia.8.6mm
   25mm dia.19mm
   50mm dia.44mm
  
 
Specification
RangeFINFIB (<1100nm)FIB
(greater than or equal to1100nm)
FIJFIRFIW
CWL tolerance (nm)+0.7, -0.4±2±3±2±5±7
HBW tolerance (nm)+0.7±2±3±2±5±8
Bandwidth ratios*      
10% BW/HBW1.741.351.741.351.131.05
1% BW/HBW3.211.993.211.991.301.18
0.1% BW/HBW6.092.926.092.921.601.36
0.01% BW/HBW12.684.4112.684.412.041.69
Blocking type & specificationInduced transmittance filter
10-4 absolute, 200-3500+
  Dielectric stacks: 10-4 ave, 10-3 abs,
x-ray to 1150nm
No of cavities (min)232357
      

Interference Filter Glossary
Bandwidth (HBW, FWHM): Width of the passband; specifically, the difference between the two wavelengths at which the transmittance is half the peak value. Similarly, 10% bandwidth (10% BW) is measured between points where T=10% of peak, etc.

Blocking: Rejection of any energy outside the passband. Absolute blocking is the transmittance level not exceeded at any point in the specified wavelength range. Average blocking is a value averaged over a range.

Cavity: The basic element from which a filter is constructed, consisting of two reflective coating stacks with a spacer layer in between. Our standard range is based on a series of three cavities and therefore a squarer shape of passband.

Centre wavelength (CWL): The wavelength midway between the half-power points which define bandwidth (see above)

Transmittance (T): The guaranteed minimum value of peak transmittance of the filter (not necessarily occurring at the centre wavelength)

Technical Notes
  · To estimate the transmittance near the passband, use the bandwidth ratios given in “specifications” e.g. 340FIB12 has HBW-10; for FIB range 1% BW/HBW=1.99,so 1% BW-19.9; .e transmittance ill be 1% of pea (about 0.3% absolute) at 340nm ±(19.9/2), i.e. about 30nm and 350nm.
  · For light incident at an angle the centre wavelength λo (1-k sin²θ) where k is approximately 0.24 for FIW filters and 0.11 for all others.
  · The CWL shifts towards the longer wavelengths with increasing temperature at about 0.1nm/K


  
 
      . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .